TKQ3 Automatic Transfer Switches

product guide£º

TKQ3 series automatic transfer switches are suitable for AC50HZ ,rated voltage 380V, DC rated voltage up 220V,rated electric current to 1600A.The switches are used in the infrequent on and off circuit.

¡¡¡¡¡¡TKQ3¡¡¡¡¡¡-- ¡¡¡¡¡¡100A¡¡¡¡¡¡ / ¡¡¡¡¡¡3A¡¡¡¡¡¡¡¡¡¡¡¡¡¡¢ò
LTML Automatic transfer switches Appointed calorific electric current£º
125A¡¢160A¡¢200A¡¢205A¡¢400A¡¢630A¡¢1000A¡¢1250A¡¢1600A
Poles:3P¡¢4P Opgions of controllers¢ñ¡¢¢ò¡¢¢ó)

   function trait£º

Performance characteristics:
1.Full electrical engineering integrity which allows auto-control without external controller
2.The world high-tech logic control circuit with strong anti-jamming and no environmental interference.
3.The mechanism with spring powered accumulator applied in the switch main body, which allows for zero electrical arc by the feeler connection and disconnection.
Standard compliance
1.International Standard:
¡ôIEC60947-1(1998)¡¶Low Switch Voltage Equipment and Control Equipment, part one :General Rules¡·.
¡ôIEC60947-3(1999)¡¶Low Switch Voltage Equipment and Control Equipment, Switch, Isolator,Isolation switch, and Combined Electric Equipment of Fuses¡·.
¡ô IEC60947-6(1999)¡¶Low Voltage Switch Equipment and Control Equipment Multi-Function-Switch Automatic tranfer Switch Electrical Device¡·.
2.National Standard:
¡ô GB/T 14048.1-2000 ¡¶Low Switch Voltage Equipment and Control Equipment,General Rules¡·.
¡ô GB/T 14048.3-2002 ¡¶Low Switch Voltage Equipment and Control Equipmen,Switch, Isolation,Isolation switch, and Combined Electric Equipment of Fuses¡·.
GB/T14048.11-2002 ¡¶Low voltage switchgear and controlggear part6-1:Multiple function equipment automatic transfer switching equipment¡·.
Operation Emvironment :
1.Height above sea level does not exceed 2,000m;
2.Anbient temperature is not higher than 40¡æand not lower than -5¡æ;
3.Relative humidity is not larger than 95%;
4.No eTKlosive dangerous medium environment;
5.No rain and snow attack environment;
(Note:if the load isolation switch is eTKected to be used in the conditionth at the ambient temperature is higher than +40¡æ or is lower than -5¡æ-45¡æ,customers should inform to the manufactory.)
¡ôThe products have three poles, four pole , and (three poles + on and offneural pole)
¡ôCurrent grades can be divided into 100A¡¢160A¡¢250A¡¢630A¡¢1000A¡¢1250A¡¢1600A.
¡ô3 control modes(R¡¢B¡¢C)
¡ôR¡¢Municipal power supply- Municipal power supply, automatic change and automatic recovery, protection of missed phase.
¡ôB¡¢125A up to 630A Municipal power supply-Municipal power supply,automatic change and automatic recovery, over voltage or lower-voltage function.
¡ôC¡¢Municipal power supply-oil generator, automatic change and automatic recovery.Having the functions of over-voltage or lower-voltage of phase shortage protection and frequency detection.
¡ôThe switches can be padlocked to keep the position status.
¡ôUse key switch to select operation.


   protection information£º
Type
TKQ3-160
Rated isolating voltage
500
Dielectric strength
5000
Rated surge-resistant voltage
8
Rated working current
380V
AC31
125
160
AC33
125
160
AC35
125
160
220V
AC31
125
160
AC33
100
125
AC35
125
160
Motor power 380V
63
80
Rated current of anti-momentary overload Icw
20/10
Rated breaking capability
1000
Rated contacting capability
1250
Rated contacting capability for short circuit
12
Mechanical life(number of cyclie operation)
10000
Electric life (number of cyclie operation)
1000
Change-overtime ¢ñ-0-¢ò»ò¢ò-0-¢ñ(S)
1.0
¢ñ-0»ò¢ò-0(S)
0.6
Power cinsumption24V(DC)¡¢220V(AC)
75
Moment of operation
6.5
°²×°³ß´ç



 

Copyright © Shanghai TBG Electric Co., Ltd. ¡¡¡¡¡¡